Connecting Rod Reconditioning – Used Connecting Rod

RA Power Solutions undertakes reconditioning of connecting rods irrespective of their size and load factor. We have special-purpose equipment for inspection of connecting rods and repairs. Following steps are taken for reconditioning of connecting rods.

  • Connecting rods are disassembled and cleaned with a special chemical.
  • Dimensional inspection of large end and small end bore is done.
  • Connecting rod is also checked for any loss of alignment on special-purpose boring machine loaded with DRDO.
  • Dye penetrant test and MPI are done for crack detection. Special attention is given to detecting the crack in the serration area, connecting rod bolts, and bolt sitting area.
  • Machining and grinding are done to restore the original dimension of the big end and small end of connecting rods.
Connecting Rod Reconditioning
Connecting Rod Reconditioning
Reconditioning of Connecting Rod
Reconditioning of Connecting Rod

Connecting rods are inspected by a senior technician and reports are maintained.

RA Power Solutions has successfully undertaken the repair of more than 15,000 connecting rods in the last 36 years of operation. RA Power Solutions also exports reconditioned connecting rods at a low price with a guarantee.

For more information about Connecting Rod Reconditioning, Used Connecting Rod, or Connecting Rod contact us at rajshahani@rapowersolutions.com or info@rapowersolutions.com, or call us at +91 9582647131 or +91 9810012383.

Connecting Rod Assembled with Piston After Repair
Connecting Rod Assembled with Piston After Repair
Connecting Rod of Crepelle
Connecting Rod of Crepelle